dhs-2 dhs50a dc-dc converters power module type dh s 50 a 05 - o ordering information 1 series name 2 single output 3 output wattage 4 a : dc60-160v 5 output voltage 6 optional t : with mounting hole ( f 3.4 thru) 1 2 3 4 5 6 model dhs50a05 dhs50a12 dhs50a15 dhs50a24 max output wattage[w] 50.0 50.4 51.0 50.4 dc output 5v 10a 12v 4.2a 15v 3.4a 24v 2.1a specifications model dhs50a05 dhs50a12 dhs50a15 dhs50a24 input voltage[v] dc60 - 160 current[a] * 1 0.55a 0.55a 0.55a 0.55a efficiency[%] * 1 84.0typ 86.0typ 86.0typ 86.0typ output voltage[v] 5 121524 current[a] 10 4.2 3.4 2.1 line regulation[mv] 10max 24max 30max 48max load regulation[mv] 10max 24max 30max 48max ripple[mvp-p] 0 to +100 c * 2 80max 120max 120max 120max -40 to 0 c * 2 120max 150max 150max 150max 0 to 15% load * 2 160max 240max 240max 240max ripple noise[mvp-p] 0 to +100 c * 2 120max 150max 150max 150max -40 to 0 c * 2 200max 200max 200max 250max 0 to 15% load * 2 240max 300max 300max 300max temperature regulation[mv] 0 to +65 c 50max 120max 150max 240max -40 to +100 c 100max 240max 300max 480max drift[mv] * 3 20max 40max 60max 90max start-up time[ms] 200max (dcin 110v, io=100%) output voltage adjustment range[v] * 4 fixed (trm pin open), adjustable by external vr or external voltage 4.50 - 6.00 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40 output voltage setting[v] 4.97 - 5.13 11.91 - 12.29 14.76 - 15.24 23.62 - 24.38 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection[v] 6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80 remote sensing nothing remote on/off provided (neqative logic l : on, h :off) isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (20 15 c ) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (20 15 c ) output-fg ac500v 1minute, cutoff current = 100ma, dc500v 50m w min (20 15 c ) environment operating temp.,humid.and altitude -40 to +100 c (on aluminum base plate), 20 - 95%rh (non condensing) (refer to derating curve), 3,000m (10,000 feet) max storage temp.,humid.and altitude -40 to +100 c , 20 - 95%rh (non condensing), 9,000m (30,000 feet) max vibration 10 - 55hz, 49.0m/s 2 (5g), 3minutes period, 60minutes each along x, y and z axis complies with iec61373 category 1 class b impact 196.1m/s 2 (20g), 11ms, once each along x, y and z axis complies with iec61373 category 1 class b safety agency approvals ul60950-1, c-ul (csa60950-1), en60950-1 others case size/weight 58.4 x 12.7 x 37.3mm [ 2.3 x 0.5 x 1.47 inches ] (w x h x d) / 60g max cooling method conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) * 1 at rated input(dc110v) and rated load. * 2 ripple and ripple noise is measured by using measuring board. refer to the manual * 3 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 4 refer to the manual for input range. * providing heat sink as option dhs o g f j u k p f f & |